* Times Microwave LMR-400 * http://www.timesmicrowave.com/home.cgi *C1 and C2 already optimized to measured data BLK CAB 1 2 Z=50 P=30.48M V=0.85 C1=.120833 C2=.014496 MLINE:2POR 1 2 END *This model is used to find values for C1 and C2 using *cable loss specifications BLK CAB 1 2 Z=50 P=30.48M V=0.85 C1=?0 .124448 1? C2=?0 .010426 1? sline:2por 1 2 end Freq 50mhz 144mhz 222mhz 432mhz 903mhz 1296mhz 2304mhz 220mhz 450mhz 900mhz 1500mhz 2000mhz 2500mhz 2.7ghz end opt *Measured line loss for 100 ft. mline f=50mhz ms21=-1.0dB mline f=144mhz ms21=-1.45dB mline f=222mhz ms21=-1.8dB mline f=432mhz ms21=-2.6dB mline f=903mhz ms21=-3.9dB mline f=1296mhz ms21=-4.7dB mline f=2304mhz ms21=-6.7dB mline f=2.7ghz ms21=-7.2dB *Times Microwave specifications sline f=50mhz ms21=-0.9dB sline f=144mhz ms21=-1.5dB sline f=220mhz ms21=-1.8dB sline f=450mhz ms21=-2.7dB sline f=900mhz ms21=-3.9dB sline f=1500mhz ms21=-5.1dB sline f=2000mhz ms21=-6.0dB sline f=2500mhz ms21=-6.8dB end Freq MS21 MS21 GHz dB dB MLINE SLINE 0.050 -0.85 -0.86 0.144 -1.46 -1.49 0.220 -1.82 -1.85 0.222 -1.83 -1.86 0.432 -2.61 -2.63 0.450 -2.67 -2.69 0.900 -3.89 -3.88 0.903 -3.90 -3.89 1.296 -4.77 -4.73 1.500 -5.17 -5.12 2.000 -6.09 -6.00 2.304 -6.61 -6.49 2.500 -6.93 -6.79 2.700 -7.24 -7.09 *Model UT-141A 50 ohm coax *Attenuation from Bill Olson's ">50", QEX, September 1987, p.14. BLK CAB 1 2 Z=50 P=30.48M V=0.70 C1=?0 .35545 .7? C2=?0 .021408 .9? line:2por 1 2 end Freq 50mhz 144mhz 5760mhz 432mhz 220mhz 3456mhz 1296mhz 1mhz 10mhz 30mhz 100mhz 300mhz 1ghz 3ghz 10ghz end opt line f=50mhz ms21=-2.4db line f=144mhz ms21=-4.1dB line f=220mhz ms21=-5.1 line f=432mhz ms21=-7.4 line f=1296mhz ms21=-13db line f=5760mhz ms21=-30dB line f=3456mhz ms21=-22dB end Freq MS21 GHz dB LINE 0.001 -0.34 0.010 -1.09 0.030 -1.90 0.050 -2.46 0.100 -3.49 0.144 -4.21 0.220 -5.23 0.300 -6.13 0.432 -7.40 1.000 -11.49 1.296 -13.18 3.000 -20.72 3.456 -22.40 5.760 -29.76 10.000 -40.79